|
Abbott Laboratories
amplatzer pfo occluder Amplatzer Pfo Occluder, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/amplatzer+vascular+plug+ii/pmc12454762-48-7-16?v=Abbott+Laboratories Average 86 stars, based on 1 article reviews
amplatzer pfo occluder - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
Johnson & Johnson
amplatzer duct occluder ii 5 4 ![]() Amplatzer Duct Occluder Ii 5 4, supplied by Johnson & Johnson, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/amplatzer+vascular+plug+ii/pmc12684515-166-21-26?v=Johnson+%26+Johnson Average 86 stars, based on 1 article reviews
amplatzer duct occluder ii 5 4 - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
St Jude Medical
amplatzer vascular plug ![]() Amplatzer Vascular Plug, supplied by St Jude Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/amplatzer+vascular+plug+ii/pmc12813561-80-8-13?v=St+Jude+Medical Average 86 stars, based on 1 article reviews
amplatzer vascular plug - by Bioz Stars,
2026-08
86/100 stars
|
Buy from Supplier |
|
Occlutech GmbH
amplatzer vascular plug (avp ii) ![]() Amplatzer Vascular Plug (Avp Ii), supplied by Occlutech GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/amplatzer+vascular+plug+ii/pm30129782-176-7-83?v=Occlutech+GmbH Average 90 stars, based on 1 article reviews
amplatzer vascular plug (avp ii) - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Cordis corporation
amplatzer vascular plug ii ![]() Amplatzer Vascular Plug Ii, supplied by Cordis corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/amplatzer+vascular+plug+ii/pm23436298-35-3-22?v=Cordis+corporation Average 90 stars, based on 1 article reviews
amplatzer vascular plug ii - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
|
Cordis corporation
12 mm amplatzer vascular plug ii ![]() 12 Mm Amplatzer Vascular Plug Ii, supplied by Cordis corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more https://www.bioz.com/product/amplatzer+vascular+plug+ii/pm24399673-46-4-19?v=Cordis+corporation Average 90 stars, based on 1 article reviews
12 mm amplatzer vascular plug ii - by Bioz Stars,
2026-08
90/100 stars
|
Buy from Supplier |
Image Search Results
Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience
doi: 10.1161/JAHA.125.043468
Figure Lengend Snippet: A , Baseline aortic angiogram in RAO showing a 3‐mm type A PDA; B , Aortic angiogram in the same projection following deployment of an MFO 6–4 (no PTFE membrane) showing a well‐positioned device with mild residual intraprosthetic shunt; C , Baseline aortic angiogram in the lateral projection; D , Aortic angiogram (lateral projection) following device deployment confirming a well‐positioned device. MFO indicates multifunctional occluder; PDA, patent ductus arteriosus; and RAO, right anterior oblique.
Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an
Techniques: Membrane
Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience
doi: 10.1161/JAHA.125.043468
Figure Lengend Snippet: A , Laminar color flow in descending aorta; B , Color wave Doppler velocity demonstrated no obstruction in the aorta with a peak velocity of 1.5 m/s; C , The MFO device was seen with no residual shunt at postprocedural Day 1, with laminar flow into LPA; D , Color wave Doppler velocity demonstrated no obstruction in the LPA with a peak velocity of 1.5 m/s. LPA indicates left pulmonary artery; MFO, multifunctional occluder; and RPA, right pulmonary artery.
Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an
Techniques:
Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience
doi: 10.1161/JAHA.125.043468
Figure Lengend Snippet: A , Baseline lateral aortic angiogram demonstrating a 7.6 mm, Type A PDA; B , Lateral aortic angiogram following deployment of an MFO 14–12 (PTFE membrane) showing a well‐positioned device with immediate shunt occlusion. MFO indicates multifunctional occluder; and PDA, patent ductus arteriosus.
Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an
Techniques: Membrane
Journal: Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
Article Title: Off‐Label Use of the Multifunctional Occluder for Transcatheter Patent Ductus Arteriosus Closure: An International Experience
doi: 10.1161/JAHA.125.043468
Figure Lengend Snippet: A , Initial aortic angiogram in the lateral projection demonstrated a short, type B PDA (4.5 mm minimal diameter, 4 mm length); B , Aortic angiogram after release of an MFO 8–6 (no PTFE membrane) showing mild intraprosthetic shunt; C , The aortic angiogram in the lateral projection at the time of reintervention showing significant intraprosthetic residual shunt; D , The final aortic angiogram in the lateral projection following transcatheter retrieval of the MFO 8–6 and implantation of an MFO 9–5 (PTFE membrane) demonstrating a well‐positioned device with immediate shunt occlusion. The aortic disc is well conformed with a descending aortic peak velocity of 1.6 m/s at discharge. MFO indicates multifunctional occluder; and PDA, patent ductus arteriosus.
Article Snippet: The intraprocedural TTE showed device protrusion causing mild acquired aortic obstruction, leading to device retrieval and successful PDA closure with an
Techniques: Membrane
Journal: Journal of Vascular Surgery Cases, Innovations and Techniques
Article Title: Physician-modified vascular plug for entry closure of a chronic aneurysmal aortic dissection
doi: 10.1016/j.jvscit.2025.102100
Figure Lengend Snippet: Procedure for making the physician-modified vascular plug (PMVP) and intraoperative angiogram of the PMVP placement technique. A , An expanded polytetrafluoroethylene (ePTFE) prosthetic patch shaped and drilled in the center of the patch and an Amplatzer Vascular Plug. B, Completed PMVP. C, After 2 disks were deployed on the false lumen by unsheathing, the third was deployed in the true lumen. Successful occlusion was confirmed by the angiogram before deployment.
Article Snippet: To make the PMVP, we used an 8-mm Amplatzer Vascular Plug (AVP II; St Jude Medical), which was approximately 2 mm larger than the diameter of the intimal defect, and an expanded polytetrafluoroethylene (ePTFE) prosthetic patch (Gore Preclude Pericardial Membrane; W. L. Gore).
Techniques: Modification
Journal: Journal of Vascular Surgery Cases, Innovations and Techniques
Article Title: Physician-modified vascular plug for entry closure of a chronic aneurysmal aortic dissection
doi: 10.1016/j.jvscit.2025.102100
Figure Lengend Snippet: Occlusion image using a physician-modified vascular plug (PMVP). AVP II , Amplatzer Vascular Plug II; ePTFE , expanded polytetrafluoroethylene.
Article Snippet: To make the PMVP, we used an 8-mm Amplatzer Vascular Plug (AVP II; St Jude Medical), which was approximately 2 mm larger than the diameter of the intimal defect, and an expanded polytetrafluoroethylene (ePTFE) prosthetic patch (Gore Preclude Pericardial Membrane; W. L. Gore).
Techniques: Modification